RITA type triple-axis spectrometer (TAS)
|
Name | Unit | Description | Default |
---|---|---|---|
ITAR | mA | Relative neutron yield from the spallation target. Value relative to 2009 | 1.0 |
L0 | Angs | Centre of generated wavelength distribution from source | 4.045 |
BPL | - | Band Pass Low factor, multiplied on source wavelength L0 to allow neutrons with wavelengths with lambda {BPL*L0,BPH*L0} to be traced from the source. | 0.97 |
BPH | - | Band Pass High factor, multiplied on source wavelength L0 to allow neutrons with wavelengths with lambda {BPL*L0,BPH*L0} to be traced from the source. | 1.03 |
MONO_N | 1 | Order of reflection used on mono | 1 |
MONOFORCE | 1 | If set, monochromator is flat | 0 |
MONO_MOS_H | min | Monochromator, horizontal mosaicity | 37 |
MONO_MOS_V | min | Monochromator, vertical mosaicity | 37 |
EI | meV | Incoming neutron energy. Also used to set range of energy monitors | 0 |
EF | meV | Outgoing neutron energy. Also used to set range of energy monitors | 0 |
EN | meV | Energy transferred in crystal | 0 |
SM | 1 | ||
SS | 1 | Scattering configuration signs. 'W' is SM=1,SS=-1,SA=1 | -1 |
SA | 1 | ||
QH | rlu | Measurement QH position in crystal | 0 |
QK | rlu | Measurement QK position in crystal | 0 |
QL | rlu | Measurement QL position in crystal | 0 |
QM | Angs-1 | Wavevector transferred in sample, use QM=0 if (QH,QK,QL) is specified | 1.8051 |
AS | Angs | Sample lattice parameter A | 4.95 |
BS | Angs | Sample lattice parameter B | 4.95 |
CS | Angs | Sample lattice parameter C | 4.95 |
AA | deg | Angle between lattice vectors B,C | 90 |
BB | deg | Angle between lattice vectors C,A | 90 |
CC | deg | Angle between lattice vectors A,B | 90 |
AH | rlu | First reciprocal lattice vector in scattering plane, X | 0 |
AK | rlu | First reciprocal lattice vector in scattering plane, Y | 1 |
AL | rlu | First reciprocal lattice vector in scattering plane, Z | 0 |
BH | rlu | Second reciprocal lattice vector in scattering plane, X | 1 |
BK | rlu | Second reciprocal lattice vector in scattering plane, Y | 0 |
BL | rlu | Second reciprocal lattice vector in scattering plane, Z | 0 |
INFILTER | 1 | Flag to indicate if mono-block filter is in or out | 0 |
INFILTERFILE | string | An input file of wavevector vs transmission to use with incoming filter | "Be.trm" |
COLL_MS | deg | Primary collimator max divergence | 80 |
MST | m | Monochromator TOP slit | 40 |
MSB | m | Monochromator BOTTOM slit | 40 |
MSL | m | Monochromator LEFT slit | 40 |
MSR | m | Monochromator RIGHT slit | 40 |
PTHICK | m | Thickness of perspex attenuator | 1e-3 |
PERSPEX | 1 | Flag to indicate if perspex attenuator is in or out | 0 |
SAMPLE | 1 | 1 is incoherent scatterer, 2 is powder, 3 is single crystal. | 1 |
SAMPLEFILE | string | Name of samplefile (with reflectionlist etc) | "default" |
MOS | - | Isotropic 'mosaicity' of single crystal | 100 |
DD_D | - | spead of lattice parameter | 1e-3 |
SAMPLESIZE | m | Length, height and width of single crystal sample, or radius and height of phonon sample | 0.01 |
BARNS | 1 | If set the flag indicates that reflection list structure factors are in units of barns, otherwise fm^2 | 1 |
AAX | - | -4.95 | |
AAY | - | Orientation vector of unit cell, single_crystal | 0 |
AAZ | - | 0 | |
BBX | - | 0 | |
BBY | - | Orientation vector of unit cell, single_crystal | 0 |
BBZ | - | 4.95 | |
CCX | - | 0 | |
CCY | - | Orientation vector of unit cell, single_crystal | 4.95 |
CCZ | - | 0 | |
A1 | deg | Monohromator rotation angle | 0 |
A2 | deg | Monohromator take-off angle | 0 |
A3 | deg | Sample rotation angle | 0 |
A4 | deg | Sample take-off angle | 0 |
AA5 | deg | Analyzer rack rotation angle | 0 |
A6 | deg | Analyzer take-off angle | 0 |
TILT | deg | Tilt angle out of plane of the sample scattering vector out of plane (rotation around z of the A3 arm) | 0 |
SST | m | Sample TOP slit | 100 |
SSB | m | Sample BOTTOM slit | 100 |
SSL | m | Sample LEFT slit | 100 |
SSR | m | Sample RIGHT slit | 100 |
OUTFILTER | 1 | Flag to indicate if the outbound filter is in or out | 1 |
OUTFILTERFILE | string | An input file of wavevector vs transmission to use with outgoing filter | "Be.trm" |
ANAFORCE | 1 | If set the analyzer is forced flat | 0 |
AA5 | deg | Analyzer rack rotation angle | 0 |
C1 | deg | Analyzer blade 1 position | 0 |
C2 | deg | Analyzer blade 2 position | 0 |
C3 | deg | Analyzer blade 3 position | 0 |
C4 | deg | Analyzer blade 4 position | 0 |
C5 | deg | Analyzer blade 5 position | 0 |
C6 | deg | Analyzer blade 6 position | 0 |
C7 | deg | Analyzer blade 7 position | 0 |
C8 | deg | Analyzer blade 8 position | 0 |
C9 | deg | Analyzer blade 9 position | 0 |
COARSE | 1 | Flag to indicate if Detector collimator is in or out | 1 |
LC | deg | Detector-collimator angle of the leftmost blade | 4 |
RC | deg | Detector-collimator angle of the rightmost blade | 3 |
REP | 1 | Repetition factor of virtual_input or Monochromator/Sample/Analyzer SPLITs | 1 |
VIRTUALOUT | 1 | If set, flag indicates that a Virtual source is created after the monochromator collimator | 0 |
VIRTUALIN | 1 | If set, flag to indicates that Virtual source is used after the monochromator collimator | 0 |
SOURCEFILE | string | Name of file to be used/genereated as virtual input/output | "Vin_default.dat" |
verbose | 1 | print TAS configuration. 0 to be quiet | 1 |
RITA_II.instr